RK0YG302 © Danfoss 04/2007 1
ADAP-KOOL® Refrigeration control systems
Contents
Introduction ....................................................................................... 4
Compressor- and condenser controls
..............................................6
Introduction ............................................................................................................... 6
Capacity control ........................................................................................................8
EKC 331T .........................................................
8
AK-PC 530 .....................................................12
AK-PC 840 .....................................................18
AK-PC 730 .....................................................20
AKC 25H1 ......................................................
22
AKC 25H3 ......................................................23
AKC 25H5 ......................................................24
Water chiller control ..............................................................................................25
AKC 25H7 ......................................................25
AK-CH 650 ....................................................26
Dry cooler ..................................................................................................................28
AK-PC 420 .....................................................28
Liquid injection in the suction line ..................................................................30
EKC 319A .......................................................
30
Speed control of compressor and condenser
................................ 32
Introduction .............................................................................................................32
AKD 2800 ......................................................33
AKD 5000 .....................................................34
Accessories for AKD ..................................35
RGE ..................................................................36
Evaporator controls and thermostatic expansion valves
.............38
Introduction .............................................................................................................38
Temperature control .............................................................................................40
EKC 100
..........................................................40
EKC 102
..........................................................42
Refrigeration appliance controls ......................................................................50
EKC 301
..........................................................50
EKC 202..........................................................56
EKC 202D ......................................................62
AK-CC 210 .....................................................
70
AK-CC 250 .....................................................79
AK-CC 450 .....................................................80
Media temperature control ................................................................................82
EKC 361
..........................................................82
EKC 368..........................................................86
Evaporator controls and electrically operated
expansion valves
.............................................................................90
Introduction .............................................................................................................90
Refrigeration appliance controls ......................................................................92
EKC 414A .......................................................
92
EKC 414A1 ....................................................
96
EKC 414C1 ................................................. 10
1
EKC 514B1 ................................................. 10
6
AK-CC 550 .................................................. 112
AK-CC 750 .................................................. 114
AKC 114-116 .............................................
116
AKC 121A ...................................................
117
Cold storage room control ............................................................................... 118
AKC 72A .....................................................118
AKC 121B ...................................................
119
AKC 151R ................................................... 12
0
Vista de pagina 0
1 2 3 4 5 6 ... 195 196

Indice de contenidos

Pagina 1 - Contents

RK0YG302 © Danfoss 04/2007 1ADAP-KOOL® Refrigeration control systemsContentsIntroduction ...

Pagina 2

10 RK0YG302 © Danfoss 05/2007 Menu surveySW: 1.1xEKC 331TFunctionPara-me-terMin. Max.FactorysettingNormal displayShows the signal from the temperatur

Pagina 3

100 RK0YG302 © Danfoss 05/2007 OrderingAdditional information!Manual: RS8DUEKC 414A1Description Type Code no.Refrigeration control controller with pl

Pagina 4

RK0YG302 © Danfoss 04/2007 101EKC 414C1Inject ON functionThe expansion valve closes when the signal at the 230 V input is removed. In this way it

Pagina 5 - ADAP-KOOL®

102 RK0YG302 © Danfoss 05/2007 Modulating controlEKC 414C1EKC 414C1Liquid supplyThe supply of liquid is controlled on the basis of signals from three

Pagina 6

RK0YG302 © Danfoss 04/2007 103Menu surveySW 1.3xEKC 414C1FunctionPara-me-terMin. Max.Fac-toryset-tingsNormal displayShows the temperature at the

Pagina 7

104 RK0YG302 © Danfoss 05/2007 DataEKC 414C1Continued from previous pagePara- meterMin. Max.Fac.settingAKV-ON denitionWhen the ON input is cut out r

Pagina 8 - Capacity control

RK0YG302 © Danfoss 04/2007 105OrderingAdditional information!Manual: RS8DFEKC 414C1DescriptionType Code no.Refrigeration control controller with

Pagina 9

106 RK0YG302 © Danfoss 05/2007 EKC 514B1EKC 514B1Data communicationApplicationThe controller is a complete control unit for refrigeration appli-ances

Pagina 10 - EKC 331T

RK0YG302 © Danfoss 04/2007 107EKC 514B1On/O controlModulating controlDemand-dependent defrostingLiquid supplyThe liquid supply is regulated base

Pagina 11

108 RK0YG302 © Danfoss 05/2007 EKC 514B1Menu surveySW = 1.2xFunctionPara-meterMin. Max.Factory settingNormal displayShows the temperaturen (weighted

Pagina 12 - AK-PC 530

RK0YG302 © Danfoss 04/2007 109EKC 514B1Continued from previous pageManual control of outputs:OFF=No override1: Light relay is ON2: Compressor rel

Pagina 13 - C = compressor, L = Unloader

RK0YG302 © Danfoss 04/2007 11Data communicationBlackBrownBlueOrderingType Function Ordering EKC 331T Capacity controller 084B7105 EKA 175 Dat

Pagina 14 - To be continued

110 RK0YG302 © Danfoss 05/2007 EKC 514B1DataOrderingDescriptionType Code No.Refrigeration appliance control(with plug)EKC 514B1 084B8009Display unit

Pagina 15

RK0YG302 © Danfoss 04/2007 111

Pagina 16

112 RK0YG302 © Danfoss 05/2007 AK-CC 550AK-CC 550ApplicationComplete refrigeration appliance control with great exibility to adapt to all types of r

Pagina 17

RK0YG302 © Danfoss 04/2007 113AK-CC 550Output used for Setting12345678910FanRail heatCompressorCompressor 2DefrostingDefrosting 2Suction line val

Pagina 18 - AK-PC 840

114 RK0YG302 © Danfoss 05/2007 AK-CC 750AK-CC 750ApplicationAK-CC 750 controllers are complete regulating units which together with valves and sensor

Pagina 19

RK0YG302 © Danfoss 04/2007 115AK-CC 750OrderingDataAdditional information!Manual: RS8EMThe installation of data communications must comply with t

Pagina 20 - AK-PC 730

116 RK0YG302 © Danfoss 05/2007 AKC 114-116AKC 114-116ApplicationAKC controllers for up to three evaporators in refrigeration appliances and cold roo

Pagina 21

RK0YG302 © Danfoss 04/2007 117Energy savings fromFan/rail heater pulsation/light controlDefrost stop according to temperatureModulating temperatu

Pagina 22 - AKC 25H1

118 RK0YG302 © Danfoss 05/2007 Additional information!Technical brochure: RC8ABAKC 72AAKC 72AApplicationAKC 72A controller primarily for cold room

Pagina 23 - • Internal day/night clock

RK0YG302 © Danfoss 04/2007 119Additional information!Technical brochure: RC1HCFunction description: RC1MDAKC 121BAKC 121BApplicationAKC controll

Pagina 24 - Function description: RC1J5

12 RK0YG302 © Danfoss 05/2007 AK-PC 530Compressors and unloaders can be combined in various ways. AK-PC 530ApplicationThe controller is used for capa

Pagina 25

120 RK0YG302 © Danfoss 05/2007 Additional information!Technical brochure: RC4JDAKC 151RAKC 151RApplicationAKC controller for cold room and cold store

Pagina 26 - AK-CH 650

RK0YG302 © Danfoss 04/2007 121

Pagina 27 - Manual: RS8ER

122 RK0YG302 © Danfoss 05/2007 EKC 312Water chiller controlApplicationThe controller and valve can be used where there are requirements to accurat

Pagina 28 - Dry cooler

RK0YG302 © Danfoss 04/2007 123Superheat functionYou may choose between two kinds of superheat, either:• Adaptive superheat or• Load-dened super

Pagina 29

124 RK0YG302 © Danfoss 05/2007 Menu surveySW =1.2xEKC 312FunctionPara-meterMin. Max.Fac.Set-tingsNormal displayShows the actual superheat/ valve&apos

Pagina 30 - EKC 319A

RK0YG302 © Danfoss 04/2007 125DataOrderingType Function Code No.EKC 312 Superheat controller 084B7250EKA 175Data communication module (accessorie

Pagina 31

126 RK0YG302 © Danfoss 05/2007 EKC 315A Water chiller application Air cooler applicationEKC 315AApplicationThe controller and valve can be used wh

Pagina 32

RK0YG302 © Danfoss 04/2007 127EKC 315ASuperheat functionYou may choose between two kinds of superheat, either:• Adaptive superheat or• Load-den

Pagina 33 - AKD 2800

128 RK0YG302 © Danfoss 05/2007 Menu surveySW =1.3xEKC 315AFunctionPara-meterMin. Max.Factory settingNormal displayShows the actual superheat/ valve&a

Pagina 34 - AKD 5000

RK0YG302 © Danfoss 04/2007 129DataOrderingType Function Code no.EKC 315A Superheat controller 084B7086EKA 175Data communication module (accessor

Pagina 35 - Accessories for AKD

RK0YG302 © Danfoss 04/2007 13Sequential (rst in - last out)The relays are here cut in in sequence – rst relay number 1, then 2, etc.Cutout tak

Pagina 36

130 RK0YG302 © Danfoss 05/2007 ApplicationThe controller and valve can be used where there are require-ments to accurate control of superheat and t

Pagina 37

RK0YG302 © Danfoss 04/2007 131Superheat functionYou may choose between two kinds of superheat, either:• Adaptive superheat or• Load-dened super

Pagina 38

132 RK0YG302 © Danfoss 05/2007 Menu surveySW =1.2xEKC 316AFunctionPa-ram-eterMin. Max.Fac.sett.Normal displayShows the actual superheat/ valve's

Pagina 39

RK0YG302 © Danfoss 04/2007 133DataOrderingType Function Code No.EKC 316A Superheat controller 084B7088EKA 175Data communication module (accessori

Pagina 40 - Temperature control

134 RK0YG302 © Danfoss 05/2007 SystemA signal transmitter will constantly measure the refrigerant liquid level in the reservoir - the controller wi

Pagina 41 - Technical data

RK0YG302 © Danfoss 04/2007 135Pump reservoirModulating control of injection makes for a more stable liquid level and suction pressure.Separator o

Pagina 42

136 RK0YG302 © Danfoss 05/2007 Menu surveyEKC 347SW = 1.1FunctionPa-ram-eterMin. Max.Fac.set-tingNormal displayRead the measured liquid level - % 50.

Pagina 43

RK0YG302 © Danfoss 04/2007 137DataOrderingAdditional information!Manual: RS8AXSupply voltage24 V a.c. +/-15% 50/60 Hz, 60 VA(the supply voltage i

Pagina 44 - Menu survey EKC 102A

138 RK0YG302 © Danfoss 05/2007 AK-WirelessApplication• Units for monitoring and data collection of temperatures.• Can be installed in all system

Pagina 45 - SW = 1.1X

RK0YG302 © Danfoss 04/2007 139ImportantInstallation of data communication cables and repeaters must comply with the requirements contained in the

Pagina 46 - EKC 102D

14 RK0YG302 © Danfoss 05/2007 AK-PC 530Menu surveyTo be continuedSequence1. o61 must be set as the rst parameter. This parameter determines which o

Pagina 47 - (115 V)(115 V)(115 V)

140 RK0YG302 © Danfoss 05/2007 AccessoriesIO modules for the AK seriesIntroductionOne of the control series can be expanded as the size of the syst

Pagina 48 - Weight = 170 g

RK0YG302 © Danfoss 04/2007 141IO modulerType Analog inputs On/O outputs On/o supply voltage (DI signal)Analog outputsModule with switchesCode

Pagina 49

142 RK0YG302 © Danfoss 05/2007 24 V On: DI > 10 V a.c. O: DI < 2 V a.c.115/230 V On: DI > 80 V a.c. O: DI < 24 V a.c.AK-XM 101A/1

Pagina 50

RK0YG302 © Danfoss 04/2007 143AK-XM 204A/BExtension moduleAK-XM 204A/BFunction The module contains 8 relay outputs.AK-XM 204B has eight change-ov

Pagina 51

144 RK0YG302 © Danfoss 05/2007 max. 10 VAK-XM 205A/BMax. 230 VAC-1: max. 4 A (ohmic)AC-15: max. 3 A (Inductive)Keep the safety distance!Low and high

Pagina 52 - Electrical connection

RK0YG302 © Danfoss 04/2007 145AK-OB 101A/XM 107AExtension moduleAK-XM 107AFunctionThe module contains eight digital inputs for pulse measuring or

Pagina 53

146 RK0YG302 © Danfoss 05/2007 AK-PS 075/150/250AK-PS 07518 VAAK-PS 15036 VAAK-PS 25060 VAExtension moduleAK-PS 075/150/250 Transformer module/Power

Pagina 54

RK0YG302 © Danfoss 04/2007 147AO1AO2AK-OB 003A/XM 208BAO1AO2+-+-Extension moduleAK-OB 003AFunction The module contains two analog voltage outputs

Pagina 55

148 RK0YG302 © Danfoss 05/2007 DisplayEKA 161/162/163/164 ApplicationThe displays may be used in conjunction with some of the control-lers in the E

Pagina 56

RK0YG302 © Danfoss 04/2007 149EKA 161 - 164 Supply 12 V +/-15% (from controller)Display/operationReadout accuracy in measuring range: 0,1°CEKA 16

Pagina 57

RK0YG302 © Danfoss 04/2007 15AK-PC 530*) This setting is only possible if data communication module is mounted in the controller To be continued

Pagina 58

150 RK0YG302 © Danfoss 05/2007 Display consoleDisplay consoleThis console can be used for a display of the type EKA 163 or EKA 164.The console can b

Pagina 59 - Start-up:

RK0YG302 © Danfoss 04/2007 151EKA 165EKA 165The display can be used with compressor controls of the type AK-PC 530. The display will show P0 or P

Pagina 60 - Data communication

152 RK0YG302 © Danfoss 05/2007 AKA 14/AKA 15AKA 14ApplicationTemperature display is used with controllers of the type AKC. External ttingFunctionLC

Pagina 61 - Weight = 200 g

RK0YG302 © Danfoss 05/2007 153ermometerEKA 151EKA 151ApplicationThe thermometer is an independent unit for showing the temperature at a refriger

Pagina 62 - EKC 202D

154 RK0YG302 © Danfoss 05/2007 AKS 11, 12, 21Temperature sensorsAKS 11, AKS 12, AKS 21ApplicationThe sensor is recommended for accurate temperatur

Pagina 63

RK0YG302 © Danfoss 04/2007 155AKS 11, AKS 12, AKS 21AKS 11AKS 21A, AKS 21MAKS 21W in welded versionAKS 21WPocket in welded version for AKS 21WAK

Pagina 64

156 RK0YG302 © Danfoss 05/2007 EKS 111EKS 111ApplicationThis sensor is primarily used with controls of the type EKC 202, AK-CC 210 and EKC 301, but

Pagina 65

RK0YG302 © Danfoss 04/2007 157EKS 211EKS 211ApplicationThis sensor is primarily used with controls of the type EKC 100 where the tolerance can be

Pagina 66

158 RK0YG302 © Danfoss 05/2007 Pressure transmittersAKS 32, AKS 33 and AKS 32RIntroductionAKS 32 and AKS 33 are pressure transmitters that measure

Pagina 67

RK0YG302 © Danfoss 04/2007 159OrderingAKS 32, version 1 → 5 VAKS 33, version 4 → 20 mA1) 1/4-18 NPT. 2) Thread ISO 228/1 - G 3/8 A (BSP).3) 7

Pagina 68

16 RK0YG302 © Danfoss 05/2007 AK-PC 530P0 pressure transmitter’s working range - min. value o20 -1 bar 0 bar -1.0P0 pressure transmitter’s working r

Pagina 69

160 RK0YG302 © Danfoss 05/2007 AKS 32RAKS 32, AKS 33AKS 32, AKS 33 and AKS 32RVersion with DIN 43650 plugDimensions and weightsAdditional information

Pagina 70 - AK-CC 210

RK0YG302 © Danfoss 05/2007 161AKS 41Level transmitterAKS 41IntroductionAKS 41 is a liquid level transmitter used to measure the liquid level in r

Pagina 71

162 RK0YG302 © Danfoss 05/2007 AKV 10, AKV 15, AKV 20ApplicationAKV are electrically operated expansion valves designed for refrigerating plant.The

Pagina 72 - Hot gas defrost

RK0YG302 © Danfoss 04/2007 163Rated capacity and Ordering1) Rated capacities are based on Condensing temperature tc = 32°C Liquid temperat

Pagina 73 - Heating function

164 RK0YG302 © Danfoss 05/2007 AKV10, AKV 15, AKV 20Spare partsAKV 10AKV 15Gasket set: Code no. 068F5263Contents: 30 pcs. O-rings 10 pcs.Cu-gask

Pagina 74

RK0YG302 © Danfoss 04/2007 165AKVA 10 AKVA 15, AKVA 20AKVA are electrically operated expansion valves designed for ammonia refrigerating plant. T

Pagina 75

166 RK0YG302 © Danfoss 05/2007 Rated capacity and Ordering1) Rated capacities are based on Condensing temperature tc = 32°C Liquid temperature

Pagina 76

RK0YG302 © Danfoss 04/2007 167Spare partsAKVA 10AKVA 15AKVA 20AKVA 10, AKVA 15, AKVA 20FilterCode No. Contents068F054010 pc. lters10 pc. Al. ga

Pagina 77 - Coordinated defrost via

168 RK0YG302 © Danfoss 05/2007 Coils for expansion valves The coils are used together with expansion valves types AKV and AKVA.Data3-core cableThe ex

Pagina 78

RK0YG302 © Danfoss 04/2007 169

Pagina 79 - AK-CC 250

RK0YG302 © Danfoss 04/2007 17Additional information!Manual: RS8EJDataOrderingType Function OrderingAK-PC 530 Capacity controller 084B8007EKA 163B

Pagina 80 - AK-CC 450

170 RK0YG302 © Danfoss 05/2007 ETSETSApplicationETS is a series of electrically operated expansion valves for precise liquid injection in evaporators

Pagina 81

RK0YG302 © Danfoss 04/2007 171ETSStepper motor switch sequence:↑ CLOSING ↑STEPCoil I Coil II↓ OPENING ↓Red Green White Black1+-+-2+- -+3-+-+4-++-

Pagina 82 - Media temperature control

172 RK0YG302 © Danfoss 05/2007 ICMMotor valveApplicationICM valves are intended for regulation of expansive processes in liquid lines with or without

Pagina 83 - Actuator temperature

RK0YG302 © Danfoss 04/2007 173DesignConnections There is a very wide range of connection types available with ICM valves:D: Butt weld, DIN (2448)

Pagina 84

174 RK0YG302 © Danfoss 05/2007 KVSKVSApplicationKVS is a series of electrically operated suction modulating control valves for AC transport and ref

Pagina 85 - Connections

RK0YG302 © Danfoss 04/2007 175KVSStepper motor switch sequence:↓ Opening ↓↑ Closing↑STEPCoil I Coil IIRed Green White Black1 +-+-2+--+3 -+-+4-++-

Pagina 86 - Refrigeration

176 RK0YG302 © Danfoss 05/2007 GDGas detectorAdditional information!Data sheet: RD7HAThe installation of data communications must comply with the r

Pagina 87

RK0YG302 © Danfoss 04/2007 177Type of gasAll models Standard With LCD displayIP 65 version EExd Low Temp –40/+40CType Range [PPM] Alarm limits. L

Pagina 88

178 RK0YG302 © Danfoss 05/2007 AK-SMSystem managerSystem manager AK-SM__ is a system unit for use with controls in the AK- series.The system manage

Pagina 89

RK0YG302 © Danfoss 04/2007 179AK-SM 720Used where data communication takes place using LON RS 485 or MOD-BUS.200 controllers can be connected whi

Pagina 90

18 RK0YG302 © Danfoss 05/2007 AK-PC 840AK-PC 840Application AK-PC 840 is a complete regulating unit for capacity control of compressors and condenser

Pagina 91

180 RK0YG302 © Danfoss 05/2007 AK-ST 500ApplicationOperational software for AK controllersFunction The programme is an advanced software tool for ope

Pagina 92 - EKC 414A

RK0YG302 © Danfoss 04/2007 181EM 100EM100The EM100 provides a web based graphical user interface of a store which allows a range of daily users t

Pagina 93

182 RK0YG302 © Danfoss 05/2007 IntroductionThe system unit in an ADAP-KOOL® refrigeration system contains over-riding functions which transfer signal

Pagina 94

RK0YG302 © Danfoss 04/2007 183Day/night controlThis function transmits a signal to selected controllers. The signal can be used for raising the t

Pagina 95

184 RK0YG302 © Danfoss 05/2007 AK-SM 350AK-SM 350ApplicationThe unit is a combined data collection unit and monitoring unit for smaller refrigerati

Pagina 96

RK0YG302 © Danfoss 04/2007 185AK-SM 350DataTypeMea-suring pointsDescription Language Code No.AK-SM 350 16With inputs for PT 1000 ohm &PTC 100

Pagina 97

186 RK0YG302 © Danfoss 05/2007 AK-SC 255AK-SC 255ApplicationThe feature-lled AK-SC 255 system controller is the heart of your control and monitori

Pagina 98

RK0YG302 © Danfoss 04/2007 187Furhter information!Manual: RS.8D.M/DKRCE.EC.000.M2.22ImportantInstallation of data communication cables and repeat

Pagina 99

188 RK0YG302 © Danfoss 05/2007 GatewaysAKA 241, AKA 243 and AKA 245 gateways are system components for use together with controllers in ADAP-KOOL®

Pagina 100 - EKC 414A1

RK0YG302 © Danfoss 04/2007 189AKA 21Only for DANBUSS data communication.This unit is only recommended for small systems and for use in service si

Pagina 101 - EKC 414C1

RK0YG302 © Danfoss 04/2007 19AK-PC 840Type Function Application Language Code no.ControllerAK-PC 840Controller for capacity control of compres-so

Pagina 102 - On/O control

190 RK0YG302 © Danfoss 05/2007 IntroductionThe system unit in an ADAP-KOOL® refrigeration system contains overriding functions which transfer signals

Pagina 103

RK0YG302 © Danfoss 04/2007 191Day/night controlThis function transmits a signal to selected controllers. The signal can be used for raising the t

Pagina 104

192 RK0YG302 © Danfoss 05/2007 AKA 231ModemApplicationThe AKA 231 is a modem for use together with ADAP-KOOL®Refrigeration system control. It can t

Pagina 105

RK0YG302 © Danfoss 04/2007 193AKA 222/223AKA 222/223RepeaterApplicationThe module is a repeater for use together with ADAP-KOOL® control systems

Pagina 106 - EKC 514B1

194 RK0YG302 © Danfoss 05/2007 Ordering survey AK seriesis list is intended for customers who know our products in the AKC series and need an over

Pagina 107 - Demand-dependent defrosting

RK0YG302 © Danfoss 04/2007 195Type Description Language Code no.AKC 25H1 Compressor control GB, DE, FR 084B2017AKC 25H1 Compressor control GB, ES

Pagina 108

196 RK0YG302 © Danfoss 05/2007

Pagina 109

2 RK0YG302 © Danfoss 05/2007 Water chiller control ... 122EKC

Pagina 110

20 RK0YG302 © Danfoss 05/2007 AK-PC 730AK-PC 730Additional information!Manual: RS8EKOrderingApplicationAK-PC 730 is particularly well-suited to capac

Pagina 111

RK0YG302 © Danfoss 04/2007 21AK-PC 730ExampleThe example below uses 2 no. AK-PC 730 to control a complete cascade system with R404A for refrigera

Pagina 112 - AK-CC 550

22 RK0YG302 © Danfoss 05/2007 AKC 25H1AKC 25H1 is a capacity controller for compressors and condensors.AKC 25H1 controls up to nine stages distribute

Pagina 113 - Designation

RK0YG302 © Danfoss 04/2007 23AKC 25H3The control has the same functions as AKC 25H1, but can additionally be used to control two independent refr

Pagina 114 - AK-CC 750

24 RK0YG302 © Danfoss 05/2007 AKC 25H5The controller has the same functions as the AKC 25H1 but also oers the possibility of controlling the dieren

Pagina 115

RK0YG302 © Danfoss 05/2007 25AKC 25H7AKC 25H7 is a complete brine cooler control unit that has been developed for indirect refrigerating systems

Pagina 116 - AKC 114-116

26 RK0YG302 © Danfoss 05/2007 ApplicationAK-CH 650 is for capacity control of chillers. The controller can control compressors, fans, pumps, defrosti

Pagina 117 - AKC 121A

RK0YG302 © Danfoss 04/2007 27Additional information!Manual: RS8ERAK-CH 650ExampleCompressorsCompressor capacity is controlled by charge temperatu

Pagina 118 - Cold storage room control

28 RK0YG302 © Danfoss 05/2007 AK-PC 420ApplicationAK-PC 420 is a complete capacity control of a dry cooler including fans, three-way valve, pumps a

Pagina 119 - AKC 121B

RK0YG302 © Danfoss 04/2007 29

Pagina 120 - AKC 151R

RK0YG302 © Danfoss 04/2007 3System units ...178System unit 1 ...

Pagina 121

30 RK0YG302 © Danfoss 05/2007 EKC 319AApplicationThe controller limits the pressure gas temperature in compressors by opening up for liquid injecti

Pagina 122 - Water chiller control

RK0YG302 © Danfoss 04/2007 31Menu surveySW = 1.1x*) This setting will only be possible if a data communication module has been installed in the c

Pagina 123

32 RK0YG302 © Danfoss 05/2007 Speed control of compressor and condenserIntroductionAKD 2800AKD-Variable Speed Drives are engineered to optimize per

Pagina 124

RK0YG302 © Danfoss 04/2007 33AKD 2800AKD 2800AKD 2800 is a frequency converter for use in refrigeration system in book form design and with local

Pagina 125

34 RK0YG302 © Danfoss 05/2007 AKD 5000Type Rated Power[kW]Outp. curr. 160% cont. Compressor ApplicationOutput. curr. 110% cont. condenser fan or HVA

Pagina 126 - EKC 315A

RK0YG302 © Danfoss 04/2007 35Accessories for AKDAccessories for AKDType Code No. DescriptionTerminal cover195N1900 AKD 2803-2815, 200-240 V, AKD

Pagina 127

36 RK0YG302 © Danfoss 05/2007 RGERGEType Code No. Refrigerants Motor rating [A]Voltage [V]No. of phasesCurrent [A]Adj. range[bar]P-band [bar]Factory

Pagina 128

RK0YG302 © Danfoss 04/2007 37

Pagina 129

38 RK0YG302 © Danfoss 05/2007 Evaporator controls and thermostatic expansion valvesThermostatic expansion valves are used in traditional refrigerat

Pagina 130 - EKC 316A

RK0YG302 © Danfoss 04/2007 39Comparison of controls in this sectionTemperature control of refrigeration appliances and cold storage roomsTemperat

Pagina 131

4 RK0YG302 © Danfoss 05/2007 Danfoss has s a comprehensive oer to the food retail industry that consists of electronic controls, compressors, cond

Pagina 132

40 RK0YG302 © Danfoss 05/2007 EKC 100EKC 100Temperature controlIntroductionThe controller is used for temperature control of refrigeration plant.Op

Pagina 133

RK0YG302 © Danfoss 04/2007 41Type Function Voltage Number Code No.EKC 100Temperature controller230 V 60 pcs 084B8610115 V 60 pcs 084B8611Ordering

Pagina 134 - Liquid level control

42 RK0YG302 © Danfoss 05/2007 EKC 102EKC 102Application• The controller is used for temperature control refrigeration appli-ances and cold room• Def

Pagina 135

RK0YG302 © Danfoss 04/2007 43EKC 102EKC 102AController with one relay output and one temperature sensor.Temperature control at start/stop of comp

Pagina 136

44 RK0YG302 © Danfoss 05/2007 EKC 102SW = 1.1xFactory settingIf you need to return to the factory-set values, it can be done in this way:- Cut out th

Pagina 137

RK0YG302 © Danfoss 04/2007 45EKC 102SW = 1.1XMenu survey EKC 102B and EKC 102CRegulation starts when the vol-tage is on.Alarm code displayA1Hig

Pagina 138 - AK-Wireless

46 RK0YG302 © Danfoss 05/2007 ParametersMin.-valueMax.-valueFactory settingFunction CodesNormal operationTemperature (set point) --- -50°C 50°C 2°CT

Pagina 139 - AK-WD 250

RK0YG302 © Danfoss 04/2007 47EKC 102Power supply230 V a.c. or 115 V a.c. See controller.SensorsSair is thermostat sensors. Saux is an extra senso

Pagina 140 - Accessories

48 RK0YG302 © Danfoss 05/2007 Additional information!Manual: RS8DYEKC 102Weight = 170 gDataSupply voltage 230 V a.c.(115 V) +10/-15 %. 1.5 VASensorsP

Pagina 141 - Module overview

RK0YG302 © Danfoss 04/2007 49

Pagina 142 - AK-XM 101A

RK0YG302 © Danfoss 04/2007 5ADAP-KOOL® Refrigeration Control System is compact, exible, easy to install and program and enables the solution to

Pagina 143 - AK-XM 204A/B

50 RK0YG302 © Danfoss 05/2007 EKC 301EKC 301ApplicationThe controller is a simple thermostat regulator in which some refrigeration-technical functi

Pagina 144 - AK-XM 205A/B

RK0YG302 © Danfoss 04/2007 51Controller application overviewExample: Controller for application number 3 satises requirement for• room temper

Pagina 145 - AK-OB 101A

52 RK0YG302 © Danfoss 05/2007 Application 1 with alarm relayApplication 2with alarm relayApplication 3 and 4 with alarm relayElectrical connectionDat

Pagina 146 - AK-PS 075/150/250

RK0YG302 © Danfoss 04/2007 53EKC 301Menu survey1) The compressor relay closes when the room temperature exceeds the setting value and dieren

Pagina 147 - AK-XM 208B

54 RK0YG302 © Danfoss 05/2007 OrderingAdditional information!Technical brochure: RD8AEManual: RS8AVEKC 301, controllers for DIN-rail mountingAccessor

Pagina 148 - EKA 161/162/163/164

RK0YG302 © Danfoss 04/2007 55

Pagina 149 - EKA 161 - 164

56 RK0YG302 © Danfoss 05/2007 EKC 202EKC 202Application• The controller is used for temperature control refrigeration appliances and cold room in s

Pagina 150 - Display console

RK0YG302 © Danfoss 04/2007 57EKC 202EKC 202AController with two relay outputs, two temperature sensors and digital input.Temperature control at s

Pagina 151

58 RK0YG302 © Danfoss 05/2007 EKC 202Menu surveySW = 1.2xParameters ControllerMin.-valueMax.-valueFactory settingActual settingFunction CodesEKC 20

Pagina 152

RK0YG302 © Danfoss 04/2007 59EKC 202Start-up:Regulation starts when the voltage is on.1 Go through the survey of factory settings. Make any neces

Pagina 153 - ermometer

6 RK0YG302 © Danfoss 05/2007 Local Control & AlarmEKC 331T Capacity controlSupervisory ControlAK-PC 530 Reliable controlSupervisory Control &a

Pagina 154 - Temperature sensors

60 RK0YG302 © Danfoss 05/2007 EKC 202ConnectionsPower supply230 V a.c.SensorsSair is thermostat sensors. S5 is a defrost sensor and is used if defros

Pagina 155 - Sensors with AMP plug:

RK0YG302 © Danfoss 04/2007 61EKC 202Additional information!Manual: RS8DZOrderingWeight = 200 gDataSupply voltage 230 V a.c. +10/-15 %. 1.5 VASens

Pagina 156 - PTC 1000 ohm/25°C

62 RK0YG302 © Danfoss 05/2007 EKC 202DApplication• The controller is used for temperature control refrigeration appliances in supermarkets• With ma

Pagina 157 - NTC 5000 ohm/25°C

RK0YG302 © Danfoss 04/2007 63SensorsUp to two thermostat sensors can be connected to the controller. The relevant application determines how.A se

Pagina 158 - Pressure transmitters

64 RK0YG302 © Danfoss 05/2007 Application Here is a survey of the controller’s eld of application.A setting will dene the relay outputs so that the

Pagina 159 - AKS 33, version 4 → 20 mA

RK0YG302 © Danfoss 04/2007 65Menu surveySW = 2.0xEKC 202DParametersEL-diagram numberMin.-value Max.-valueFactory settingActual settingFunction Co

Pagina 160 - AKS 32, AKS 33 and AKS 32R

66 RK0YG302 © Danfoss 05/2007 EKC 202DInput signal on DI2. Function: (0=not used. 1=status on DI2. 2=door function with alarm when open. 3=door alarm

Pagina 161 - Level transmitter

RK0YG302 © Danfoss 04/2007 67Connections(115 V a.c.)Data communicationEKC 202DPower supply230 V a.c. (115 V version available)SensorsS3 and S4 ar

Pagina 162 - Expansion valves

68 RK0YG302 © Danfoss 05/2007 DataSupply voltage 230 V a.c.(or 115 V version) +10/-15 %. 2.5 VASensors 3 pcs o eitherPt 1000 orPTC (1000 ohm/25°C)

Pagina 163

RK0YG302 © Danfoss 04/2007 69OrderingType Function Voltage supply Code No.EKC 202DRefrigeration controller without data communication but prepare

Pagina 164

RK0YG302 © Danfoss 04/2007 7Brief outline about some of the controlsEKC 331T controller is used for capacity regulation of compres-sors or conden

Pagina 165 - AKVA 10 AKVA 15, AKVA 20

70 RK0YG302 © Danfoss 05/2007 Application• The controller is used for temperature control refrigeration appliances in supermarkets• With many prede

Pagina 166

RK0YG302 © Danfoss 04/2007 71SensorsUp to two thermostat sensors can be connected to the controller. The relevant application determines how.A se

Pagina 167

72 RK0YG302 © Danfoss 05/2007 Application Here is a survey of the controller’s eld of application.A setting will dene the relay outputs so that the

Pagina 168 - Coils for expansion valves

RK0YG302 © Danfoss 04/2007 735 6 7 8 9 10 AK-CC 210Refrigeration control with two compressors This group of applications can be used if the

Pagina 169

74 RK0YG302 © Danfoss 05/2007 Menu surveyAK-CC 210SW = 2.0xParameters EL-diagram numberMin.-valueMax.-valueFactory settingFunction Codes 1 234567891

Pagina 170

RK0YG302 © Danfoss 04/2007 75AK-CC 210*) Can only be set when regulation is stopped (r12=0)**) Can be controlled manually, but only when r12=-1**

Pagina 171 - Additional information!

76 RK0YG302 © Danfoss 05/2007 ConnectionsCoordinated defrost via cable connectionsThe following controllers can be connected up in this way:AK-CC 210

Pagina 172 - Motor valve

RK0YG302 © Danfoss 04/2007 77DataCoordinated defrost via data communicationAK-CC 210Supply voltage 230 V a.c. +10/-15 %. 2.5 VASensors 3 pcs o e

Pagina 173

78 RK0YG302 © Danfoss 05/2007 OrderingAdditional information!Manual: RS8EPType Function Code no.AK-CC 210Refrigeration controller without data commun

Pagina 174 - Evaporation pressure valve

RK0YG302 © Danfoss 04/2007 79AK-CC 250This control is a variant of AK-CC 210. It diers on the following points:• Fixed MOD-BUS data communicati

Pagina 175 - Electrical data

8 RK0YG302 © Danfoss 05/2007 Capacity regulationThe cut-in capacity is controlled by signals from the connected pressure transmitter (temperature s

Pagina 176 - Gas detector

80 RK0YG302 © Danfoss 05/2007 AK-CC 450AK-CC 450ApplicationComplete refrigeration appliance control with great exibility to adapt to all types of re

Pagina 177 - Dimensions

RK0YG302 © Danfoss 04/2007 81AK-CC 450ApplicationsHere is an overview of the controller’s usage options.A setting will congure input and outputs

Pagina 178 - System unit 1

82 RK0YG302 © Danfoss 05/2007 EKC 361Start/stopEKC 361Media temperature controlApplicationThe controller and valve can be used where there are stri

Pagina 179 - AK-PI 200

RK0YG302 © Danfoss 04/2007 83The allowed temperature in the actuator determines the evaporating pressureActuator temperatureEKC 361Very accurate

Pagina 180 - Web-based operation

84 RK0YG302 © Danfoss 05/2007 EKC 361Supply voltage24 V a.c. +/-15% 50/60 Hz, 80 VA(the supply voltage is galvanically separated from the input and

Pagina 181

RK0YG302 © Danfoss 04/2007 85ConnectionsAdditional information!Manual: RS8AECVQ/CVMQ/KVQEKC 361Data communication

Pagina 182 - Introduction

86 RK0YG302 © Danfoss 05/2007 LED's on front panelKVS - signalRefrigerationFanDefrostEKC 368EKC 368ApplicationController and valve are used wher

Pagina 183 - Defrost control

RK0YG302 © Danfoss 04/2007 87EKC 368Very accurate temperature controlWith this system where controller and valve have been adapted for optimum us

Pagina 184 - System unit 2

88 RK0YG302 © Danfoss 05/2007 EKC 368Function Para-meterMin. Max.Fac. set-tingNormal displayShows the temperature at the room sensor - °CGive the low

Pagina 185

RK0YG302 © Danfoss 04/2007 89Data communicationKVS 2122232442 - 54 white black green redAdditional information!Manual: RS8DGEKC 368OrderingType F

Pagina 186 - System unit 3

RK0YG302 © Danfoss 04/2007 9C = compressor, L = UnloaderEKC 331TRelay moduleThe controller can also be used as a relay module where the relays in

Pagina 187

90 RK0YG302 © Danfoss 05/2007 Evaporator controls and electrically operated expansion valvesSince the introduction of the AKV pulse-width modulated

Pagina 188 - System unit 4

RK0YG302 © Danfoss 04/2007 91Type EKC 414A EKC 414A1 EKC 414C1 EKC 514B1 AK-CC 550 AK-CC 750Number of evaporators 111114Supply = 230 V a.c. XXXXX

Pagina 189 - Technical brochure: RC0XL

92 RK0YG302 © Danfoss 05/2007 Refrigeration appliance controlsEKC 414AEKC 414ADigital inputA digital input can be dened for one of the follow

Pagina 190

RK0YG302 © Danfoss 04/2007 93EKC 414ALiquid supplyThe supply of liquid is controlled on the basis of signals from the pressure transmitter, temp

Pagina 191

94 RK0YG302 © Danfoss 05/2007 Menu surveySW: 1.1xEKC 414AFunctionParame-terMin. Max.Factory settingsNormal displayShows the temperature at the select

Pagina 192

RK0YG302 © Danfoss 04/2007 95DataOrderingAdditional information!Manual: RS8CKEKC 414AThe installation of data communications must comply with the

Pagina 193 - Repeater

96 RK0YG302 © Danfoss 05/2007 EKC 414A1EKC 414A1ApplicationThe controller is a complete control unit for refrigeration appliances with integrated ref

Pagina 194 - Appendix

RK0YG302 © Danfoss 04/2007 97On/O controlModulating controlEKC 414A1Liquid supplyThe supply of liquid is controlled on the basis of signals from

Pagina 195

98 RK0YG302 © Danfoss 05/2007 Menu surveySW: 1.0xEKC 414A1FunctionParameterMin. Max.FactorysettingsNormal displayShows the temperature at the selecte

Pagina 196

RK0YG302 © Danfoss 04/2007 99Data*) AC 15 load in accordance with EN 60947-5-1EKC 414A1Supply voltage 230 V +10/-15%, 50/60 Hz, 5 VASensorsPt 100